888¼¯ÍŹÙÍøvip

²úƷͼƬ²úÆ·¼ò½é¹Ø¼ü¸öÐÔ»úÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM2000
4G+20¶þ²ãÖÎÀíÐÍ»¥»»Ö÷Ìâ°å
²úÆ·¼ò½é

SICOM2000-L2-2G2GE20TÊÇרΪǶÈëʽ¼¯³ÉÀûÓÿª·¢µÄ¶þ²ãÍø¹ÜÐÍǶÈëʽ¹¤ÒµÒÔÌ«ÍøÖ÷Ì⻥»»Ä £¿£¿ £¿ £¿£¿£¿ £¿£¿é£¬£¬£¬£¬£¬£¬£¬£¬×î´óÖ§³Ö20¸ö°ÙÕ×¼±¾çÒÔÌ«Íø½Ó¿Ú¼°4¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú£¬£¬£¬£¬£¬£¬£¬£¬ÆäÖÐ2¸öΪǧÕ×COMBO¿Ú¡£¡£¡£¡£¡£¡£¡£¡£Ö§³Ö¿íÁìÓòµÄ¿É²Ù×÷ζȣ¨-40¡æ~70¡æ+£©£¬£¬£¬£¬£¬£¬£¬£¬³ß´çΪ80mmx95mmx16mm(³¤x¿íx¸ß)£¬£¬£¬£¬£¬£¬£¬£¬Êʺ϶à¶Ë¿ÚͨѶ¡¢¸ß¶È¼¯³É»¯µÄÀûÓõÄÒªÇ󡣡£¡£¡£¡£¡£¡£¡£

SICOM2000-L2-2G2GE20TϵÁй¤ÒµÒÔÌ«Íø»¥»»Ä £¿£¿ £¿ £¿£¿£¿ £¿£¿éÖ§³ÖDRPºÍRSTP»·ÍøÈßÓàºÍ̸£¬£¬£¬£¬£¬£¬£¬£¬Äܹ»½Ã½Ý×éÍø£¬£¬£¬£¬£¬£¬£¬£¬²¢Âú×ã<20msÍøÂç¶ÏÏ߸´Ô­¹¦·ò¡£¡£¡£¡£¡£¡£¡£¡£³ýÒÔÌ«Íø½Ó¿Ú±í£¬£¬£¬£¬£¬£¬£¬£¬¸ÃÄ £¿£¿ £¿ £¿£¿£¿ £¿£¿é»¹Ìṩ15¸öGPIO½Ó¿Ú¿Éͨ¹ýºÅÁîǰ½øÐÐÅäÖü°²éÎÊ£¬£¬£¬£¬£¬£¬£¬£¬ÒÔÂú×ã·ÖÆçÀûÓó¡¾°±ØÒª½øÐÐ״̬²éÎÊ»òÊä³öµÄÐèÒª¡£¡£¡£¡£¡£¡£¡£¡£

¹Ø¼ü¸öÐÔ

¸ÃϵÁÐ×î¶àÖ§³Ö2¸öǧÕ×µç¿Ú+2¸öǧÕ×Combo¿Ú+20¸ö°ÙÕ×µç¿Ú

Ö§³ÖÓ²¼þ¸´Î»Ö°ÄÜ

ÈÕÖ¾Óëϵͳ·¨Ê½Ê¹ÓöÀÁ¢FLASHÌá¸ß²úÆ·²»±äÐÔ

*Ìṩ15¸öGPIO½Ó¿Ú

Ö§³ÖDT-RingºÍ̸×å,RSTP/MSTP,DRP»·ÍøÈßÓà

* ÈçÐè½ç˵GPIOÇëÁªÏµ888¼¯ÍŹÙÍøvip

»úÄܲÎÊý
²úÆ·¹æ¸ñ
ÐÐÒµ³ß¶È EMI FCC CFR47 Part 15,EN55022/CISPR22,Class A
EMS IEC61000-4-2 (ESD) ¡À6kV (contact), ¡À8kV (air)
IEC61000-4-3£º(RS) 20V/m (80MHz-2GHz)
IEC61000-4-4£º(EFT) Power Port: ¡À2kV; Data Port: ¡À2kV
IEC61000-4-5£º (Surge) Power Port: ¡À1kV/DM, ¡À2kV/CM
IEC61000-4-6£º(CS)10V (150kHz-80MHz)
IEC61000-4-8£º(Power frequency magnetic field)50Hz 100A/m
IEC61000-4-9£º(Pulsed magnetic field )300A/m
IEC61000-4-29£º(Voltage Short interruptions) 10ms 100%
»úе IEC61373(Õñ¶¯ºÍ³å»÷) IEC60068-2-32(×ÔÓɵøÂä)
»·¾³ ¹¤×÷ζȣº-40¡æ¡«+70¡æ+
Öü´æÎ¶ȣº-40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È£º5¡«95%ÎÞÄý¶
»úе½á¹¹ ³ß´ç£º95mm x 80mm x 15.9mm
×°Ö÷½Ê½£ºÇ¶Èëʽ
ÅúʾµÆ ÔËÐÐÅúʾµÆ:Run
»·ÍøÅúʾµÆ:Ring,Master
µçÔ´ÅúʾµÆ:PWR
½Ó¿ÚÅúʾµÆ:Link/ACT
½Ó¿Ú ǧÕ׶˿ڣº10/100/1000Base-T(X)
°ÙÕ׶˿ڣº10/100Base-T(X)
Console¿Ú£ºRS232
¸´Î»°´Å¥
µçÔ´Êä³ö£º3.3VDC½Ó¿Ú
LED£º28·LED½ÚÔì½Ó¿Ú
GPIO£º15·½Ó¿Ú
»¥»»ÊôÐÔ ÓÅÏȼ¶¶ÓÁУº8
VLANÊý£º4K
VLAN ID£º1¡«4093
×é²¥×éÊý£º64
MAC񡜧16K
°ü»º³åÇø£º4Mbit
×î´ó°üת·¢ÂÊ£º17.9Mpps
»¥»»ÑÓ³¤£º<10us
³ß¶È IEEE 802.3i(10Base-T)
IEEE 802.3u(100Base-T)
IEEE 802.3ab(1000Base-T)
IEEE 802.3x(Á÷¿Ø)
IEEE 802.1p(ÓÅÏȼ¶)
IEEE 802.1Q(VLAN)
IEEE 802.1s£¨MSTP£©
IEEE 802.1w£¨RSTP£©
IEEE 802.1X£¨½Ó¼û½ÚÔìºÍ̸£©
Èí¼þÖ°ÄÜ
µçÔ´ ÊäÈëµçѹ£º5VDC£¨µçѹµßô¤5%£©
¹¦ºÄ£ºÓ×ÓÚ20W
ʱÖÓÖÎÀí Ö§³ÖSNTP client
Ö§³ÖPTPv2 TCģʽ
IPÖÎÀí Ö§³ÖDHCP server/client/server option 82
ÖÎÀíÓëÊØ»¤ Ö§³ÖConsole,Telnet,WEBÖÎÀí·½Ê½
Ö§³ÖSNMPv1/v2c/v3,¿Éͨ¹ýKyvision¼¯ÖÐÖÎÀí
Ö§³ÖFTP/TFTPÎļþ´«Êä¼°Èí¼þÉý¼¶
Ö§³ÖRMON
Ö§³ÖIP/MACì¶Ü¸æ¾¯,µçÔ´¸æ¾¯,¶Ë¿Ú¸æ¾¯,»·¸æ¾¯
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖSyslog
Ö§³ÖLLDP
·þÎñÖÊÁ¿ÖÎÀí Ö§³ÖACL
Ö§³Ö802.1pºÍTOS/DiffServ,Ö§³ÖSP,WRR¶ÓÁе÷¶È
°²È«¼¼Êõ Ö§³ÖIEEE 802.1x
Ö§³ÖHTTPs/SSL, SFTP Client
Ö§³ÖSSH
Ö§³ÖRADIUS
Ö§³ÖTACACS+
Ö§³ÖÓû§·Ö¼¶
×é²¥¼¼Êõ Ö§³ÖIGMP-snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
ÈßÓàÖ°ÄÜ Ö§³ÖDT-ring, DT-ring+, DT-VLANºÍ̸×壬£¬£¬£¬£¬£¬£¬£¬×ÔÓú¹¦·ò<50ms
Ö§³ÖDRP/DHP, ×ÔÓú¹¦·ò<20ms
Ö§³ÖRSTP/MSTP
»¥»»Ö°ÄÜ Ö§³ÖVLAN,PVLAN
Ö§³ÖGVRP
Ö§³Ö¶Ë¿Ú¾ÛºÏ
Ö§³ÖLACP
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö¶Ë¿ÚÏÞËÙ,¹ã²¥·ç±©ÒÖÔì
»úе³ß´ç

VIP888¡¤(Öйú´ó½)¹Ù·½ÍøÕ¾

ÏÎ½ÓÆ÷£º2 x SAMTEC “SFM-150-02-S-D-A-K-TR”¡£¡£¡£¡£¡£¡£¡£¡£ÏÎ½ÓÆ÷×°Öø߶È6.35m£¬£¬£¬£¬£¬£¬£¬£¬É¢ÈÈÆ÷×°Öÿ׿׾¶3.25mm¡£¡£¡£¡£¡£¡£¡£¡£

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

²úÆ·ÐͺŠÊä³ö½Ó¿Ú ±¸×¢
SICOM2000-L2-C-2G2GE20T 2¸öǧÕ×Combo¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸öǧÕ×µç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬20¸ö°ÙÕ×µç¿Ú Èý·ÀÍ¿¸²
SICOM2000-L2-2G2GE20T 2¸öǧÕ×Combo¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸öǧÕ×µç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬20¸ö°ÙÕ×µç¿Ú  
×ÊÁÏÏÂÔØ
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿