888¼¯ÍŹÙÍøvip

²úƷͼƬ²úÆ·¼ò½é¹Ø¼ü¸öÐÔ»úÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
Aquam8112-1U
12G¶Ë¿Ú¶þ²ãÖÎÀíÐ͹¤ÒµÒÔÌ«Íø»¥»»»ú
²úÆ·¼ò½é

Aquam8112-1U±ðÀëÊÇרΪ¹ì·½»Í¨³©ÒµÉè¼ÆµÄ¶þ²ãÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø»¥»»»ú£¬£¬£¬£¬£¬ Ö§³Ö 12¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú£¬£¬£¬£¬£¬ÆäÖÐ4 ¸öΪǧÕ×Bypass¶Ë¿Ú£¬£¬£¬£¬£¬PoEÐͺſÉÔ̺¬8¸öǧÕ×»ò°ÙÕ×PoEÍø¿Ú¡£¡£¡£¡£¡£¡£²úƷΪ1U»ú¼ÜʽװÖ㬣¬£¬£¬£¬Ö§³Ö¿íÁìÓò(-40~+70¡æ)µÄ¿É²Ù×÷ζȣ¬£¬£¬£¬£¬Âú×ã EN50155¡¢EN50121µÈ¹ì·½»Í¨³©Òµ³ß¶ÈµÄÒªÇ󡣡£¡£¡£¡£¡£Ö§³ÖÈ«¶Ë¿Ú M12½Ó¿Ú´ó¾Ö£¬£¬£¬£¬£¬±£Õ϶˿ÚÏνӼ°Õû»úµÄÃÜ·âÐÔºÍÀιÌÐÔ£¬£¬£¬£¬£¬ÓÈÆäÊʺÏÓÐÇ¿ÁÒµÄÕñ¶¯ºÍ³å»÷µÄÀûÓó¡¾°¡£¡£¡£¡£¡£¡£Aquam8112-1U ÒÔÌ«Íø»¥»»»úÖ§³ÖÓÃÓÚ IP µØÖ·×Ô¶¯·ÖÅäµÄ DHCP ºÍ̸¼°¶àÖÖ DHCP option Ñ¡Ï£¬£¬£¬£¬²¢ÇÒÖ§³Ö DRP ºÍ RSTP »·ÍøÈßÓàºÍ̸£¬£¬£¬£¬£¬Äܹ»½Ã½Ý×éÍø£¬£¬£¬£¬£¬ÒÔÂú×ãÌú·Êг¡µÄÐèÒª¡£¡£¡£¡£¡£¡£Aquam8112-1UϵÁл¥»»»úÇкÏIEC62443-4-2¹¤ÒµÍøÂ簲ȫ³ß¶È¡£¡£¡£¡£¡£¡£

¹Ø¼ü¸öÐÔ

¸ÃϵÁÐ×î¶àÖ§³Ö12¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú

Ö§³ÖBypassÖ°ÄÜ

µçÔ´½Ó¿Ú¼°¶Ë¿ÚÏÎ½ÓÆ÷ÐͺÅÖ§³ÖM12

Ö§³ÖDRPºÍRSTP»·ÍøÈßÓà±£»£»£»£»£»£»£»¤

ÇкÏEN50155ºÍEN50121ÐÐÒµ³ß¶ÈÒªÇó,רΪ¹ì·½»Í¨ÀûÓÃÉè¼Æ

ÇкÏIEC62443-4-2¹¤ÒµÍøÂ簲ȫ³ß¶È

1U»ú¼ÜʽװÖÃ

Ö§³Ö802.3af/at PoE¹©µç£¬£¬£¬£¬£¬×î´óÊä³ö¹¦ÂÊ60W

»úÄܲÎÊý
Èí¼þÖ°ÄÜ
Ö§³ÖºÍ̸ IEEE 802.3ab£¬£¬£¬£¬£¬ÓÃÓÚǧÕ×ÒÔÌ«Íø
IEEE 802.3u,ÓÃÓÚ°ÙÕ×ÒÔÌ«Íø
IEEE 802.1Q£¬£¬£¬£¬£¬ÓÃÓÚVLAN ÏóÕ÷
IEEE 802.1p£¬£¬£¬£¬£¬ÓÃÓÚQoS·þÎñµÈ¼¶
»¥»»»úÖ°ÄÜ Ö§³Ö¾²Ì¬VLAN£¬£¬£¬£¬£¬²»ÉÙÓÚ64¸ö£¬£¬£¬£¬£¬±àºÅÁìÓò1-4094
Ö§³Ö8K MACµØÖ·±í
»·Íø×ÔÓú¹¦·ò²»´óÓÚ50ms
QOSÉèÖò»ÉÙÓÚ6¸ö¶ÓÁÐ
Ö§³Ö¶Ë¿ÚÁ÷¿Ø £¬£¬£¬£¬£¬¶Ë¿Ú×ÔÊÊÓ¦
Ö§³Ö¹ã²¥¡¢×é²¥¡¢Î´Öªµ¥²¥·ç±©ÒÖÔì
Ö§³Ö¾²Ì¬ºÍ¶¯Ì¬MACµØÖ·ºÍMACµØÖ·ÀÏ»¯
ʱÖÓÖÎÀí Ö§³ÖSNTP client
Ö§³ÖNTP client
ÈßÓ༼Êõ Ö§³ÖRSTP (Rapid Spanning Tree Protocol)
Ö§³ÖDRP£¬£¬£¬£¬£¬×ÔÓú¹¦·ò<50ms
Ö§³ÖÁ´Â·¾ÛºÏ(LACP, IEEE802.3ad)
×é²¥¼¼Êõ Ö§³ÖIGMP snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
ÍøÂ簲ȫ Ö§³ÖIEEE 802.1x(Éí·ÝÈÏÖ¤ºÍÊÚȨ)
Ö§³ÖHTTPs/SSL
Ö§³ÖSSH
Ö§³Ö±¾µØRADIUS server, Ò²Ö§³Ö¶Ô±í²¿µÄRADIS Serverת·¢Éí·ÝÈÏÖ¤ÐÅÏ¢
Ö§³ÖTACACS+
ÖÎÀíÓëÊØ»¤ Ö§³ÖConsole, Telnet, WEBÖÎÀí·½Ê½
Ö§³Öͨ¹ýÍø¹ÜϵͳԶ³ÌÅúÁ¿ÅäÖÃ
Ö§³ÖSNMPÖÎÀí, Ö§³ÖSNMPv1/v2c/v3
Ö§³ÖTCP/UDP, Ping,
Ö§³Öͨ¹ýFTP/TFTP/HTTP/HTTPs½øÐÐÈí¼þºÍÅäÖõÄÉÏ´«ÏÂÔØ
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖLLDPºÍLLDP MIB£¨802.1ab£©
Õï¶Ï¼¼Êõ Ö§³ÖIP/MACì¶Ü¸æ¾¯, µçÔ´¸æ¾¯, ¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯
Ö§³ÖÈÕÖ¾Ö°ÄÜ
IPÖÎÀí Ö§³ÖIPv4
Ö§³ÖDHCP server/option12
Ö§³ÖDHCP Relay Agent Information Option
Ö§³ÖDHCP Client
Ö§³ÖARP
·þÎñÖÊÁ¿ÖÎÀí Ö§³ÖACL
Ö§³Ö»ùÓڶ˿ں͵ØÖ·µÄÊý¾ÝÁ÷½ÚÔìºÍÏÞ¶È
Ö§³Ö802.1p TOS/DiffServ, Ö§³ÖSP, WRR¶ÓÁе÷¶È
²úÆ·¹æ¸ñ
LED PWRÅúʾµÆ£º
ÂÌÉ«³£ÁÁ£ºµçÔ´ÊäÈëÕý³££»£»£»£»£»£»£»
Ã𣺵çÔ´ÊäÈëÒì³£
RUNÅúʾµÆ£º
ÂÌÉ«³£ÁÁ£ºÏµÍ³Òì³£»£»£»£»£»£»£»òÔÚÆô¶¯
ÂÌÉ«ÉÁ¶¯£ºÏµÍ³Õý³£
AlarmÅúʾµÆ£º
ºìÉ«³£ÁÁ£ºÏµÍ³¹ÊÕÏ
Ãð£ºÏµÍ³Õý³£
ǧÕ×/°ÙÕ×½Ó¿ÚÅúʾµÆ£º
ÂÌÉ«³£ÁÁ£ºÇ°Ãæ°å¶Ë¿ÚÏνÓ
ÂÌÉ«ÉÁ¶¯£ºÇ°Ãæ°å¶Ë¿Úº±¼û¾ÝÊÕ·¢
Ãð£ºÇ°Ãæ°å¶Ë¿Ú¶Ï¿ª
»ú¿Ç ½ðÊô
É¢ÈÈ ÎÞµçÉÈ
·À»¤µÈ¼¶ IP40
³ß´ç £¨W¡ÁH¡ÁD£© 440mm x 44mm x 256.6.6mm
³ÁÁ¿(Kg) <4.27kg
×°Ö÷½Ê½ 1U»ú¼Ü×°ÖÃ
¶î¶¨µçѹֵ 110VDC
ÊäÈëµçѹÁìÓò 77~137.5VDC
¹¦ÂÊ 9.5W
µçÔ´¶Ë×ÓÀàÐÍ M12
ÈßÓàµçÔ´ Ö§³Ö
·´½Ó¡¢¹ýÔØ±£»£»£»£»£»£»£»¤ Ö§³Ö
ÐÐÒµ³ß¶È EMI: FCC CFR47 Part 15
EMS: EN50121
·À»ð: EN45545-2
°²È«: EN62368-1
¹ì·½»Í¨£ºEN50155¡¢EN50121-1¡¢EN50121-4(pending)
»úе: IEC61373 (Õñ¶¯ºÍ³å»÷)(pending)
·À»¤µÈ¼¶: IP40 Based on EN 60529(pending)
ΣÏÕ×ÊÁÏ: 2002/95/EG of the EU (RoHS)
ÍøÂ簲ȫ: ÇкÏIEC62443-4-2¹¤ÒµÍøÂ簲ȫ³ß¶È
Öʱ£ ±£½¨ÆÚ: 5Äê
»·¾³ ¹¤×÷ζÈ: -40¡ãC to +70¡ãC
´æ´¢Î¶È: -40¡ãC to +85¡ãC
Ïà¶Ôʪ¶È: 5 to 95% (ÎÞÄý¶)
»úе³ß´ç

VIP888¡¤(Öйú´ó½)¹Ù·½ÍøÕ¾

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍÆ¼öÐͺÅ

 

²úÆ·ÐͺвúÆ·ÃèÊö

Aquam8112-1U-B-4GE8GP-H6-H6

¶þ²ã1U»ú¼Üʽ³µÔØ»¥»»»ú£¬£¬£¬£¬£¬4¸öǧÕ×Bypass M12ÒÔÌ«Íøµç¿Ú£¬£¬£¬£¬£¬8¸öǧÕ×POE M12ÒÔÌ«Íøµç¿Ú£¬£¬£¬£¬£¬110VDC¹©µç

Aquam8112-1U-B-12GE-H6-H6

¶þ²ã1U»ú¼Üʽ³µÔØ»¥»»»ú£¬£¬£¬£¬£¬4¸öǧÕ×Bypass M12ÒÔÌ«Íøµç¿Ú£¬£¬£¬£¬£¬8¸öǧÕ× M12ÒÔÌ«Íøµç¿Ú£¬£¬£¬£¬£¬110VDC¹©µç

Aquam8112-1U-B-4GE8T-H6-H6

¶þ²ã1U»ú¼Üʽ³µÔØ»¥»»»ú£¬£¬£¬£¬£¬4¸öǧÕ×Bypass M12ÒÔÌ«Íøµç¿Ú£¬£¬£¬£¬£¬8¸ö°ÙÕ× M12ÒÔÌ«Íøµç¿Ú£¬£¬£¬£¬£¬110VDC¹©µç

 

¿ÉÑ¡Åä¼þ

 

SAP±àÂë

888¼¯ÍŹÙÍøvipÐͺÅ

ÀàÐÍ

ѹÏßÁìÓò

³öÏßÖ±¾¶
107100952

M12-A-4P-F-Crimp-18~16AWG

µçÔ´ÏÎ½ÓÆ÷

18~16AWG

6~8mm
107100768

M12-D-4P-M-Crimp-26~22AWG

°ÙÕ×Íø¿ÚÏÎ½ÓÆ÷

26~22AWG

6~8mm
107100245

M12-X-8P-M-Crimp

ǧÕ×Íø¿ÚÏÎ½ÓÆ÷

26~24AWG

6~7.5mm
×ÊÁÏÏÂÔØ
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿