SICOM3008GVÍø¹ÜÐÍ¿¨¹ìʽ»¥»»»úÖ§³Ö2¸öǧÕ×SFP½Ó¿ÚºÍ6¸ö°ÙǧÕ××ÔÊÊÓ¦µç¿Ú¡£¡£¡£¡£¡£SICOM3008GVÓµÓÐIP30·À»¤µÄ½ðÊô±í¿Ç£¬£¬£¬£¬£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬£¬£¬£¬£¬-40¡æ-+75¡æ¼«¶Ë»·¾³Î¶ÈÊÊÓ¦ÄÜÁ¦¼°ÓÅÁ¼µÄEMCµç´Å¼æÈÝ»úÄÜ£¬£¬£¬£¬£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ¶ñÁÓ¹¤Òµ»·¾³Ï²»±ä¿¿µÃס¹¤×÷µÄÄÜÁ¦£¬£¬£¬£¬£¬Í¬Ê±Ìṩ12~58VDCµçÔ´ÊäÈë¡£¡£¡£¡£¡£Ä¿Ç°¸Ã²úÆ·¿ÉÓÃÓÚ½»Í¨£¬£¬£¬£¬£¬Ê¯ÓÍʯ»¯£¬£¬£¬£¬£¬×Ô¶¯»¯µÈ±ØÒªÊ¹ÓÃÊÓÆµ¼à¿ØµÄ¹¤ÒµÁìÓò¡£¡£¡£¡£¡£
| ²úÆ·¹æ¸ñ | |
| ¼¼Êõ²ÎÊý | ³ß¶È IEEE802.3 IEEE802.3u IEEE802.3ab IEEE802.3z IEEE802.3x IEEE802.1p IEEE802.1Q IEEE802.1w IEEE802.1x IEEE 802.3az |
| »¥»»ÊôÐÔ | MAC±í 8K °ü»º³åÇø 4Mbit °üת·¢ÂÊ 1.5Mpps(ÿ¶Ë¿Ú) »¥»»ÑÓ³¤ <15¦Ìs ³¬³¤Ö¡ 9K |
| ½Ó¿Ú | ǧÕ×¶Ë¿Ú 1000Base-X, SFP½Ó¿Ú °ÙǧÕ××ÔÊÊÓ¦µç¿Ú 10/100/1000Base-T(X), RJ45½Ó¿Ú |
| Íø¹ÜÖ°ÄÜ | ½çÃæ CLI »ùÓÚWEBµÄÍø¹Ü½çÃæ SNMP v1,v2,v3, ¿Éͨ¹ýKyvision¼¯ÖÐÖÎÀí Telnet ¼±¾ç¸´Ô»·ºÍ̸ DT-Ring, DT-Ring+, DT-VLANºÍ̸×壬£¬£¬£¬£¬×ÔÓú¹¦·ò<50ms DRP,×ÔÓú¹¦·ò<20ms ÌìÉúÊ÷ºÍ̸ IEEE802.1d STP, IEEE802.1w RSTP, IEEE802.1s MSTP Á´Â·»ã¾Û½ÚÔìºÍ̸LACP Ö§³Ö VLANs 256 Port-based VLANs IEEE 802.1Q tag-based VLANs IEEE 802.1ad Double Tagging (Q in Q) ×é²¥ºÍ̸ IGMP v1,v2,v3 GVRP ·ç±©ÒÖÔì ×é²¥/¹ã²¥/·ç±©ÒÖÔì Á÷½ÚÔì IEEE 802.3x and Back-Pressure QoS IEEE 802.1p QoS ÓÅÏȼ¶¶ÓÁÐ 8 °²È«ÐÔ HTTPs SSH ¶Ë¿Ú°²È« »ùÓÚIPºÍMACµÄ½Ó¼û½ÚÔì IEEE 802.1xÈÏÖ¤µÄÍøÂç½Ó¼û½ÚÔì ¸üк͸´Ô »ùÓÚWEBµÄÊäÈëÊä³öÅäÖà »ùÓÚWEBµÄFirmware¸üРÕï¶Ï ϵͳÈÕÖ¾ VLAN¾µÏñ ÒÔÌ«ÍøÏνÓÕï¶Ï Link-check MIB RFC 1757 RMON 1,2,3,9 RFC 2674 Q-bridge MIB RFC-1213 MIB-II RFC-1493 bridge MIB RFC 2233 IF MIB LLDP IEEE 802.1ab DHCP Ö§³Ö SNTP/NTP Ö§³Ö ϵͳ״̬ É豸/ÒÔÌ«Íø¶Ë¿Ú״̬ |
| ÅúʾµÆ | Ç°Ãæ°åÅúʾµÆ µçÔ´ÅúʾµÆ:PWR1,PWR2 ½Ó¿ÚÅúʾµÆ:Link/ACT |
| µçÔ´ | ÊäÈëµçѹ 12~58VDC ¹¦ÂÊ <9W ·´½Ó±£»£»£»£»£»£»¤ Ö§³Ö ÈßÓà±£»£»£»£»£»£»¤ Ö§³Ö |
| »úе½á¹¹ | ±í¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½Ê½ ÌìÈ»ÀäÈ´£¬£¬£¬£¬£¬ÎÞµçÉÈ ·À»¤µÈ¼¶ IP30 ³ß´ç 108x154x61mm(W¡ÁH¡ÁD) ³ÁÁ¿ 1.3Kg ×°Ö÷½Ê½ DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
| »·¾³ | ¹¤×÷ÎÂ¶È -40¡æ¡«+75¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶ |
| Öʱ£ | MTBF >25Äê ±£½¨ÆÚ 5Äê |
| ÈÏÖ¤ | CE,FCCÈÏÖ¤ ²úÆ·×îÐÂÈÏÖ¤¶¯Ì¬Çë²éÎÊKylandÍøÕ¾ |
| ÐÐÒµ³ß¶È | EMI FCC CFR47 Part 15,EN55022/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air) IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz) IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV IEC61000-4-5(Surge) Power Port:¡À1kV/DM,¡À2kV/CM;Data Port:¡À2kV IEC61000-4-6(CS) 10V(150kHz¡«80MHz) »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(³å»÷) IEC60068-2-32(×ÔÓɵøÂä) |

²úÆ·Ñ¡ÐÍ
ÍÆ¼öÐͺÅ
|
²úÆ·ÐͺŠ|
SICOM3008GV-Ports-PS1-PS2 |
|
´úÂë½ç˵ |
´úÂëÑ¡ÐÍ |
|
Ports:¶Ë¿Ú |
2GX6GE=2×100/1000Base-X, SFP½Ó¿Ú; 6x10/100/1000Base-T(X) 8GE=8x10/100/1000Base-T(X) |
|
PS1-PS2:ÈßÓàµçÔ´ÊäÈë |
L15-L15=12-58VDC,ÈßÓàÊäÈë |