SICOM6800-DÊÇSICOM6800²úƷϵÁÐÖп¨¹ì״̬µÄ½»¸¶¼þ£¬£¬£¬£¬£¬£¬£¬¸Ã²úÆ·ÊÇÃæÏò¹¤¿Ø°²È«ÒªÇó½Ï¸ß³¡ËùÑÐÔìµÄ¹ú²ú×ÔÖ÷¿É¿ØÈý²ãÍø¹ÜÐÍÒÔÌ«Íø»¥»»»ú£¬£¬£¬£¬£¬£¬£¬Ñ¡È¡×ÔÖ÷¿É¿Ø»¥»»Ð¾Æ¬+×ÔÖ÷¿É¿ØCPU+×ÔÖ÷¿É¿Ø²Ù×÷ϵͳ¡£¡£¡£¡£¡£
SICOM6800-DÖ§³Ö4¸ö1000Base-X SFP½Ó¿Ú£¬£¬£¬£¬£¬£¬£¬8¸ö10/100/1000Base-T(X) RJ45µç¿Ú¡£¡£¡£¡£¡£Ö§³ÖDT-RingºÍ̸×å(×ÔÓú¹¦·ò<50ms)£¬£¬£¬£¬£¬£¬£¬DRP/DHP£¨×ÔÓú¹¦·ò<20ms£©£¬£¬£¬£¬£¬£¬£¬MSTP/RSTP/STP£¬£¬£¬£¬£¬£¬£¬VLAN£¬£¬£¬£¬£¬£¬£¬×é²¥£¬£¬£¬£¬£¬£¬£¬QoSµÈ·á˶µÄ¶þ²ãÈí¼þ¸öÐÔ£¬£¬£¬£¬£¬£¬£¬VRRP£¬£¬£¬£¬£¬£¬£¬OSPF£¬£¬£¬£¬£¬£¬£¬RIP£¬£¬£¬£¬£¬£¬£¬IGMP£¬£¬£¬£¬£¬£¬£¬PIM£¬£¬£¬£¬£¬£¬£¬¾²Ì¬Â·ÓɵÈÈý²ãÖ°ÄÜ£¬£¬£¬£¬£¬£¬£¬802.1x£¬£¬£¬£¬£¬£¬£¬SSH£¬£¬£¬£¬£¬£¬£¬HTTPs£¬£¬£¬£¬£¬£¬£¬Óû§·Ö¼¶µÈ°²È«¸öÐÔ£¬£¬£¬£¬£¬£¬£¬²¢Ö§³ÖCLI£¬£¬£¬£¬£¬£¬£¬Telnet£¬£¬£¬£¬£¬£¬£¬Web¶àÖÖÖÎÀí·½Ê½ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ£¬£¬£¬£¬£¬£¬£¬Õë¶ÔÒ°±í»·¾³ÊÊÓ¦ÐÔ£¬£¬£¬£¬£¬£¬£¬¸ßÔÊÊÓ¦ÐÔ£¬£¬£¬£¬£¬£¬£¬ÒÔ¼°EMC¸ß·À»¤»úÄÜÒªÇó¶ø¿ª·¢£¬£¬£¬£¬£¬£¬£¬¸ÃϵÁвúÆ·¾ß±¸ÔÚ¶ñÁÓ¹¤Òµ»·¾³Ï²»±ä¿¿µÃס¹¤×÷µÄÄÜÁ¦¡£¡£¡£¡£¡£
×î´óÖ§³Ö4¸ö1000Base-X SFP½Ó¿Ú£¬£¬£¬£¬£¬£¬£¬8¸ö10/100/1000Base-T(X) RJ45µç¿Ú
ѡȡ×ÔÖ÷¿É¿Ø»¥»»Ð¾Æ¬+×ÔÖ÷¿É¿ØCPU+×ÔÖ÷¿É¿Ø²Ù×÷ϵͳ
Ö§³ÖDT-Ring, DRPºÍ̸×å¼°RSTP, MSTPµÈ¶àÖÖÈßÓà×éÍø»úÔì
Ö§³ÖVRRP, OSPF, RIP, IGMP, PIM, ¾²Ì¬Â·ÓÉ
Ö§³ÖHTTPS/SSL, SSH, TACACS+, IEEE802.1X, RADIUS, Óû§·Ö¼¶, ¶Ë¿ÚMACµØÖ·°ó¶¨
| Èí¼þÖ°ÄÜ | |
| »¥»»Ö°ÄÜ | Ö§³ÖVLAN Ö§³ÖGVRP Ö§³Ö¶Ë¿Ú¾ÛºÏ Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö¶Ë¿ÚÏÞËÙ Ö§³Ö¹ã²¥·ç±©ÒÖÔì Ö§³ÖARP£¬£¬£¬£¬£¬£¬£¬´úÀíARP |
| ÈßÓ༼Êõ | Ö§³ÖDRP/DHP, ×ÔÓú¹¦·ò<20ms Ö§³ÖDT-Ring, DT-Ring+, DT-VLAN ºÍ̸×å, ×ÔÓú¹¦·ò<50ms Ö§³ÖRSTP/MSTP, ¼æÈÝSTP Ö§³ÖERPS£¨ITU-T G.8032£© |
| ×é²¥¼¼Êõ | Ö§³Ö¾²Ì¬×é²¥ Ö§³ÖIGMP Snooping Ö§³ÖGMRP Ö§³ÖIGMP v1/v2/v3 Ö§³ÖPIM-SM, PIM-DM |
| ·Óɼ¼Êõ | Ö§³Ö¾²Ì¬Â·ÓÉ Ö§³ÖRIPv1/v2 Ö§³ÖOSPFv2 Ö§³ÖVRRP |
| ·þÎñÖÊÁ¿ÖÎÀí | Ö§³ÖACL,¶ÔL2-L4²ãÊý¾Ý½øÐйýÂË Ö§³Ö802.1p(CoS),DSCP Ö§³ÖSP,WRR¶ÓÁе÷¶È |
| °²È« | Ö§³ÖIEEE 802.1X Ö§³ÖHTTPS/SSL Ö§³ÖSSH Ö§³ÖRADIUS Ö§³ÖTACACS+ Ö§³ÖÓû§·Ö¼¶ Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨ Ö§³ÖIP Source Guard Ö§³Ö¶Ë¿Ú¸ôÀë |
| ÖÎÀíÓëÊØ»¤ | Ö§³ÖConsole,Telnet,WEBÖÎÀí·½Ê½ Ö§³ÖSNMP v1/v2c/v3, ¿Éͨ¹ýKyvision¼¯ÖÐÖÎÀí Ö§³ÖFTP, TFTPÎļþ´«Êä¼°Èí¼þÉý¼¶ Ö§³ÖµçÔ´¸æ¾¯£¬£¬£¬£¬£¬£¬£¬IP/MACµØÖ·Ã¬¶Ü¸æ¾¯£¬£¬£¬£¬£¬£¬£¬CPU/ÄÚ´æÀûÓÃÂʸ澯£¬£¬£¬£¬£¬£¬£¬¶Ë¿Úlink״̬£¬£¬£¬£¬£¬£¬£¬¶Ë¿ÚÁ÷Á¿¸æ¾¯£¬£¬£¬£¬£¬£¬£¬¶Ë¿Ú¶ª°üÂʼ°CRC¸æ¾¯£¬£¬£¬£¬£¬£¬£¬»·¸æ¾¯£¬£¬£¬£¬£¬£¬£¬SFP ½Ó¿Ú½Ó¹Ü¹â¹¦Âʸ澯ºÍ·¢Ë͹⹦Âʸ澯 Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖSyslog Ö§³ÖRMON Ö§³ÖLLDP Ö§³ÖNQA Ö§³ÖDDM |
| IPÖÎÀí | Ö§³ÖIPv6µØÖ·ÖÎÀí Ö§³ÖDNS Ö§³ÖDHCP server/client/snooping |
| ʱÖÓÖÎÀí | Ö§³ÖNTP Client Ö§³ÖSNTP Client Ö§³ÖPTPv2 Ö§³ÖÊ±Çø¼°ÏÄʱÔìÅäÖà |
| ²úÆ·¹æ¸ñ | |
| ¼¼Êõ²ÎÊý | ³ß¶È IEEE 802.3i(10Base-T) IEEE 802.3u(100Base-TX) IEEE 802.3ab(1000Base-T) IEEE 802.3ad(¶Ë¿Ú¾ÛºÏ) IEEE 802.3z(1000Base-SX/LX) IEEE 802.3x(Á÷¿Ø) IEEE 802.1p(ÓÅÏȼ¶) IEEE 802.1Q(VLAN) IEEE 802.1w(RSTP) IEEE 802.1s(MSTP) |
| »¥»»ÊôÐÔ | ÓÅÏȼ¶¶ÓÁÐ 8 VLANÊý 4K ×é²¥×éÊý 1K ·Óɱí 8K MAC±í 32K »¥»»ÈÝÁ¿ 24Gbps °üת·¢ÂÊ 35.7Mpps °ü»º³åÇø 48Mbit »¥»»ÑÓ³¤ <10¦Ìs ³¬³¤Ö¡³¤¶È 10KB |
| ½Ó¿Ú | ǧÕ×¶Ë¿Ú 1000Base-X SFP½Ó¿Ú£»£»£»£»£»£»10/100/1000Base-T(X) RJ45µç¿Ú Console¿Ú RS232,RJ45½Ó¿Ú ¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max,60W Max |
| ÅúʾµÆ | Ç°Ãæ°åÅúʾµÆ ÔËÐÐÅúʾµÆ:Run ¸æ¾¯ÅúʾµÆ:Alarm µçÔ´ÅúʾµÆ:PWR1,PWR2 »·ÅúʾµÆ:Ring ½Ó¿ÚÅúʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú) |
| °´Å¥ | Reset:Ö§³Ö³ÁÆôºÍ¸´ÔĬÈÏÅäÖà |
| µçÔ´ | ÊäÈëµçѹ 100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)£»£»£»£»£»£»24-48VDC(18-72VDC) ½ÓÈë¶Ë×Ó 3о7.62mm¼ä¾à²åÈëʽ¶Ë×Ó£¨¸ßѹ£©/5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó£¨µÍѹ£© ¹¦ÂÊ <20W ¹ýÔØ±£»£»£»£»£»£»¤ Ö§³Ö ·´½Ó±£»£»£»£»£»£»¤ Ö§³Ö ÈßÓà±£»£»£»£»£»£»¤ Ö§³Ö |
| »úе½á¹¹ | ±í¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½Ê½ ÌìÈ»ÀäÈ´,ÎÞµçÉÈ ·À»¤µÈ¼¶ IP40 ³ß´ç 91mm¡Á139mm¡Á140mm (W¡ÁH¡ÁD) ³ÁÁ¿ 1.50Kg ×°Ö÷½Ê½ DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
| »·¾³ | ¹¤×÷ÎÂ¶È -40¡æ¡«+75¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5-95%ÎÞÄý¶ ¹¤×÷º£°Î 5000Ã× |
| Öʱ£ | MTBF 1118569h ±£½¨ÆÚ 5Äê |
| ÈÏÖ¤ | ²úÆ·×îÐÂÈÏÖ¤¶¯Ì¬Çë²éÎÊKylandÍøÕ¾ |
| ÐÐÒµ³ß¶È | EMI FCC CFR47 Part 15,EN55032/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À8kV(contact),¡À15kV(air) IEC61000-4-3(RS) 10V/m(80MHz-2GHz) IEC61000-4-4(EFT) Power Port:¡À4kV;Data Port:¡À2kV IEC61000-4-5(Surge) Power Port:¡À2kV/DM,¡À4kV/CM;Data Port:¡À2kV IEC61000-4-6(CS) 3V(10kHz-150kHz);10V(150kHz-80MHz) IEC61000-4-8(¹¤Æµ´Å³¡) 100A/m(cont.),1000A/m(1s-3s) IEC61000-4-9(Âö³å´Å³¡) 1000A/m »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(³å»÷) IEC60068-2-32(×ÔÓɵøÂä) |

²úÆ·Ñ¡ÐÍ
|
²úÆ·ÐͺŠ|
Êä³ö½Ó¿Ú |
µçÔ´ | ±¸×¢ |
|
SICOM6800-D-4GX8GE-L2-L2 |
4×1000Base-X SFP½Ó¿Ú 8×10/100/1000Base-T(X) RJ45µç¿Ú |
24-48VDC(18-72VDC) , ÈßÓàÊäÈë | |
|
SICOM6800-D-4GX8GE-HV |
4×1000Base-X SFP½Ó¿Ú 8×10/100/1000Base-T(X) RJ45µç¿Ú |
100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) , µ¥Â·ÊäÈë | |
|
SICOM6800-D-C-4GX8GE-L2-L2 |
4×1000Base-X SFP½Ó¿Ú 8×10/100/1000Base-T(X) RJ45µç¿Ú |
24-48VDC(18-72VDC) , ÈßÓàÊäÈë | Èý·ÀÍ¿¸² |
|
SICOM6800-D-C-4GX8GE-HV |
4×1000Base-X SFP½Ó¿Ú 8×10/100/1000Base-T(X) RJ45µç¿Ú |
100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) , µ¥Â·ÊäÈë | Èý·ÀÍ¿¸² |